Copyright (c) 2012 by cisco Systems, Inc.
PYRAMID platform with 2097152 Kbytes of main memory
Autoboot executing command: "boot bootdisk:s2t54-adventerprisek9-mz.SPA.155-.SY.bin"
bootdisk:%s72044-atafslib-m: Digitally Signed Release Software with key version A
Initializing ATA monitor library...
bootdisk:s2t54-adventerprisek9-mz.SPA.155-1.SY.bin: Digitally Signed Release Software with key version A
Self extracting the image... [OK]
Self decompressing the image : ################################################################################### [OK]
*** No sreloc section
Restricted Rights Legend
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
cisco Systems, Inc.
170 West Tasman Drive
San Jose, California 95134-1706
Cisco IOS Software, s2t54 Software (s2t54-ADVENTERPRISEK9-M), Version 15.5(1)SY, RELEASE SOFTWARE (fc6)
Copyright (c) 1986-2017 by Cisco Systems, Inc.
Compiled Sun 30-Apr-17 01:23 by prod_rel_team
fw_board_init : Firmware init 1 calling now
fw_board_init : Firmware init 1 completed
This is a VSS capable switch.
VSL ports can be configured in slot: 5
fw_board_init : Firmware init 2 calling now
fw_board_init : Firmware init 2 completed
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
cisco WS-C6509-E (M8572) processor (revision ) with 1785856K/262144K bytes of memory.
Processor board ID SMG1906N01B
CPU: MPC8572_E, Version: 2.2, (0x80E80022)
CORE: E500, Version: 3.0, (0x80210030)
CPU:1500MHz, CCB:600MHz, DDR:600MHz
L1: D-cache 32 kB enabled
I-cache 32 kB enabled
Last reset from s/w reset
1 Virtual Ethernet interface
54 Gigabit Ethernet interfaces
36 Ten Gigabit Ethernet interfaces
2543K bytes of non-volatile configuration memory.
--- System Configuration Dialog ---
Would you like to enter the initial configuration dialog? [yes/no]: no
*Sep 3 00:07:20.943: %VS_PARSE-4-CONFIG_WARNING: Switch bootup in Standalone mode since config register sets to skip Startup config: 0x2142
Firmware compiled 30-Apr-17 01:23 by sabind Build [26112]
*Sep 3 00:07:31.807: %PFREDUN-6-ACTIVE: Initializing as ACTIVE processor for this switch
*Sep 3 00:07:56.863: SP: Currently running ROMMON from S (Gold) region
*Sep 3 00:08:00.831: %SYS-6-STARTUP_CONFIG_IGNORED: System startup configuration is ignored based on the configuration register setting.
*Sep 3 00:08:05.783: %SYS-5-RESTART: System restarted --
Cisco IOS Software, s2t54 Software (s2t54-ADVENTERPRISEK9-M), Version 15.5(1)SY, RELEASE SOFTWARE (fc6)
Copyright (c) 1986-2017 by Cisco Systems, Inc.
Compiled Sun 30-Apr-17 01:23 by prod_rel_team
*Sep 3 00:08:07.059: %PFREDUN-6-ACTIVE: Standby initializing for SSO mode
Press RETURN to get started!
*Sep 3 00:08:07.567: %SYS-6-BOOTTIME: Time taken to reboot after reload = 147 seconds
*Sep 3 00:08:08.735: %OIR-6-INSPS: Power supply inserted in slot 1
*Sep 3 00:08:08.735: %C6KPWR-4-PSOK: power supply 1 turned on.
*Sep 3 00:08:09.407: %OIR-6-INSPS: Power supply inserted in slot 2
*Sep 3 00:08:09.407: %C6KPWR-4-PSOK: power supply 2 turned on.
*Sep 3 00:08:09.407: %C6KPWR-4-PSREDUNDANTBOTHSUPPLY: in power-redundancy mode, system is operating on both power supplies.
*Sep 3 00:08:09.407: %SYS-3-LOGGER_FLUSHED: System was paused for 00:00:00 to ensure console debugging output.
*Sep 3 00:08:10.415: %C6KENV-4-FANHPMODE: Fan-tray 1 is operating in high power mode
... existing image is ELB IDPROM format.
... existing image is ELB IDPROM format.
... existing image is ELB IDPROM format.
... existing image is ELB IDPROM format.
*Sep 3 00:08:25.527: %FABRIC-5-FABRIC_MODULE_ACTIVE: The Switch Fabric Module in slot 5 became active.
*Sep 3 00:08:30.707: %DIAG-6-RUN_MINIMUM: Module 5: Running Minimal Diagnostics...
*Sep 3 00:08:55.335: %DIAG-6-DIAG_OK: Module 5: Passed Online Diagnostics
*Sep 3 00:09:00.955: %OIR-6-SP_INSCARD: Card inserted in slot 5, interfaces are now online
*Sep 3 00:09:09.519: %FABRIC-5-FABRIC_MODULE_BACKUP: The Switch Fabric Module in slot 6 became standby
*Mar 1 00:00:03.443: DaughterBoard (Distributed Forwarding Card 4)
Firmware compiled 30-Apr-17 01:06 by sabind Build [25600]
Sep 3 00:09:42.967: %SYS-DFC1-5-RESTART: System restarted --
Cisco IOS Software, c6lc2e8 Software (c6lc2e8-SP-M), Version 15.5(1)SY, RELEASE SOFTWARE (fc6)
Copyright (c) 1986-2017 by Cisco Systems, Inc.
Compiled Sun 30-Apr-17 01:07 by prod_rel_team
Sep 3 00:09:43.027: DFC1: Currently running ROMMON from S (Gold) region
*Mar 1 00:00:03.431: DaughterBoard (Distributed Forwarding Card 4)
Firmware compiled 30-Apr-17 01:06 by sabind Build [25600]
Sep 3 00:09:43.955: %SYS-DFC2-5-RESTART: System restarted --
Cisco IOS Software, c6lc2e8 Software (c6lc2e8-SP-M), Version 15.5(1)SY, RELEASE SOFTWARE (fc6)
Copyright (c) 1986-2017 by Cisco Systems, Inc.
Compiled Sun 30-Apr-17 01:07 by prod_rel_team
Sep 3 00:09:44.015: DFC2: Currently running ROMMON from S (Gold) region
*Sep 3 00:09:51.651: %C6KENV-4-HIGHER_SLOT_EMPTY: The higher adjacent slot of module 6 might be empty. Airdam must be installed in that slot to be NEBS compliant
*Sep 3 00:09:52.023: %OIR-6-SP_INSCARD: Card inserted in slot 6, interfaces are now online
*Sep 3 00:09:58.299: %DIAG-6-RUN_MINIMUM: Module 1: Running Minimal Diagnostics...
*Sep 3 00:09:59.663: %DIAG-6-RUN_MINIMUM: Module 2: Running Minimal Diagnostics...
*Mar 1 00:00:05.719: DaughterBoard (Distributed Forwarding Card 4)
Firmware compiled 30-Apr-17 01:06 by sabind Build [25600]
Sep 3 00:09:57.911: %SYS-DFC3-5-RESTART: System restarted --
Cisco IOS Software, c6lc2e8 Software (c6lc2e8-SP-M), Version 15.5(1)SY, RELEASE SOFTWARE (fc6)
Copyright (c) 1986-2017 by Cisco Systems, Inc.
Compiled Sun 30-Apr-17 01:07 by prod_rel_team
Sep 3 00:09:58.207: DFC3: Currently running ROMMON from S (Gold) region
*Mar 1 00:00:05.679: DaughterBoard (Distributed Forwarding Card 4)
Firmware compiled 30-Apr-17 01:06 by sabind Build [25600]
Sep 3 00:10:10.571: %SYS-DFC4-5-RESTART: System restarted --
Cisco IOS Software, c6lc2e8 Software (c6lc2e8-SP-M), Version 15.5(1)SY, RELEASE SOFTWARE (fc6)
Copyright (c) 1986-2017 by Cisco Systems, Inc.
Compiled Sun 30-Apr-17 01:07 by prod_rel_team
Sep 3 00:10:10.603: DFC4: Currently running ROMMON from S (Gold) region
*Sep 3 00:10:27.611: %DIAG-6-DIAG_OK: Module 1: Passed Online Diagnostics
*Sep 3 00:10:28.347: %OIR-6-SP_INSCARD: Card inserted in slot 1, interfaces are now online
*Sep 3 00:09:03.075: STBY: SP: Currently running ROMMON from S (Gold) region
*Sep 3 00:09:25.459: %DIAG-STBY-6-RUN_MINIMUM: Module 6: Running Minimal Diagnostics...
*Sep 3 00:09:51.435: %DIAG-STBY-6-DIAG_OK: Module 6: Passed Online Diagnostics
*Sep 3 00:10:31.935: %SYS-STBY-5-RESTART: System restarted --
Cisco IOS Software, s2t54 Software (s2t54-ADVENTERPRISEK9-M), Version 15.5(1)SY, RELEASE SOFTWARE (fc6)
Copyright (c) 1986-2017 by Cisco Systems, Inc.
Compiled Sun 30-Apr-17 01:23 by prod_rel_team
*Sep 3 00:10:32.487: %SYS-STBY-3-LOGGER_FLUSHED: System was paused for 00:02:22 to ensure console debugging output.
*Sep 3 00:10:45.375: %HA_CONFIG_SYNC-6-BULK_CFGSYNC_SUCCEED: Bulk Sync succeeded
*Sep 3 00:10:45.379: %RF-5-RF_TERMINAL_STATE: Terminal state reached for (SSO)
*Sep 3 00:10:45.371: %PFREDUN-STBY-6-STANDBY: Ready for SSO mode in Default Domain
*Sep 3 00:10:51.167: %DIAG-6-DIAG_OK: Module 2: Passed Online Diagnostics
*Sep 3 00:10:52.023: %OIR-6-SP_INSCARD: Card inserted in slot 2, interfaces are now online
*Sep 3 00:11:10.599: %DIAG-6-RUN_MINIMUM: Module 3: Running Minimal Diagnostics...
*Sep 3 00:11:23.843: %DIAG-6-RUN_MINIMUM: Module 4: Running Minimal Diagnostics...
*Sep 3 00:11:54.887: %DIAG-6-DIAG_OK: Module 4: Passed Online Diagnosticsap
*Sep 3 00:11:56.399: %OIR-6-SP_INSCARD: Card inserted in slot 4, interfaces are now onlinea
Router#sh license all
License Store: Primary License Storage
License Store: Evaluation License Storage
StoreIndex: 0 Feature: TEST_FEATURE_1 Version: 1.0
License Type: Evaluation
License State: Active, Not in Use, EULA not accepted
Evaluation total period: 4 weeks 2 days
Evaluation period left: 4 weeks 2 days
License Count: Non-Counted
License Priority: None
StoreIndex: 1 Feature: TEST_FEATURE_2 Version: 1.0
License Type: Evaluation
License State: Active, Not in Use, EULA not accepted
Evaluation total period: 1 hour 0 minute
Evaluation period left: 1 hour 0 minute
License Count: Non-Counted
License Priority: None
Router#sh capability feature routing
Displaying capability information for all available features:
RC_FEATURE_APP_ROUTE enabled
RC_FEATURE_BGP_ADDPATH enabled
RC_FEATURE_BGP_CC enabled
RC_FEATURE_BGP_DIVERSEPATH enabled
RC_FEATURE_BGP_DN enabled
RC_FEATURE_BGP_ENHANCED_ERROR_HANDLING enabled
RC_FEATURE_BGP_ENHANCED_REFRESH enabled
RC_FEATURE_BGP_GLOBAL_IMPORT enabled
RC_FEATURE_BGP_GSHUT enabled
RC_FEATURE_BGP_LOCAL_AS_IBGP enabled
RC_FEATURE_BGP_MIBv2 enabled
RC_FEATURE_BGP_MULTI_CLUSTER_ID enabled
RC_FEATURE_BGP_MVPN enabled
RC_FEATURE_BGP_REMOVE_PVT_AS_ALL enabled
RC_FEATURE_BGP_RTC enabled
RC_FEATURE_BGP_SELECTIVE_ADDRESS_TRACKING enabled
RC_FEATURE_BGP_SPLIT_HORIZON enabled
RC_FEATURE_BGP_VPN_DISTINGUISHER enabled
RC_FEATURE_BGP_VPN_MCAST enabled
RC_FEATURE_BGP_WILDCARD_RT_VD enabled
RC_FEATURE_BGPv4_PIC enabled
RC_FEATURE_BGPv6_BFD enabled
RC_FEATURE_BGPv6_PIC enabled
RC_FEATURE_INTER_VRF_RPL_AND_REDIST enabled
RC_FEATURE_IPV4_STATIC_BFD enabled
RC_FEATURE_ISIS_BFD_CBIT enabled
RC_FEATURE_ISIS_BFD_IPV6 enabled
RC_FEATURE_ISIS_IPV6_ADMIN_TAG enabled
RC_FEATURE_L3VPN_INTERAS_HYBRID enabled
RC_FEATURE_L3VPN_INTERAS_HYBRID_GLOBAL enabled
RC_FEATURE_MULTICAST_LIVE_LIVE enabled
RC_FEATURE_OSPFV3_AF enabled
RC_FEATURE_OSPFV3_AREA_FILTERS enabled
RC_FEATURE_OSPFV3_BFD enabled
RC_FEATURE_OSPFV3_DC_IGNORE enabled
RC_FEATURE_OSPFV3_GR enabled
RC_FEATURE_OSPFV3_IPSEC enabled
RC_FEATURE_OSPFV3_LIMIT enabled
RC_FEATURE_OSPFV3_PECE enabled
RC_FEATURE_OSPFV3_PFX_SUP enabled
RC_FEATURE_OSPFV3_RFC1583 enabled
RC_FEATURE_OSPFV3_RFC3101 enabled
RC_FEATURE_OSPFV3_SHUTDOWN enabled
RC_FEATURE_OSPFV3_STUB enabled
RC_FEATURE_OSPF_IPE enabled
RC_FEATURE_OSPF_PFX_PRIORITY enabled
RC_FEATURE_OSPF_PFX_SUP enabled
RC_FEATURE_OSPF_RFC3101 enabled
RC_FEATURE_RECURSIVE_STATIC_ROUTE enabled
RC_FEATURE_RIP_ADVERTISE_DEFAULT enabled
RC_FEATURE_ROUTE_TAG_DOTTED enabled
RC_FEATURE_ROUTING_CONTEXT enabled
RC_FEATURE_TABLEID_FOF_LC enabled
Router#sh mod
Mod Ports Card Type Model Serial No.
--- ----- -------------------------------------- ------------------ -----------
1 24 CEF720 24 port 1000mb SFP WS-X6824-SFP SAL1909ADKH
2 24 CEF720 24 port 1000mb SFP WS-X6824-SFP SAL1909ADKG
3 16 CEF720 16 port 10GE WS-X6816-10GE SAL2002WH7D
4 16 CEF720 16 port 10GE WS-X6816-10GE SAL19048KG1
5 5 Supervisor Engine 2T 10GE w/ CTS (Acti VS-SUP2T-10G SAL1906917H
6 5 Supervisor Engine 2T 10GE w/ CTS (Hot) VS-SUP2T-10G SAL18432T0L
Mod MAC addresses Hw Fw Sw Status
--- ---------------------------------- ------ ------------ ------------ -------
1 7426.acfb.5e9c to 7426.acfb.5eb3 2.4 12.2(18r)S1 15.5(1)SY Ok
2 84b8.020b.b2a0 to 84b8.020b.b2b7 2.4 12.2(18r)S1 15.5(1)SY Ok
3 58ac.788e.27f8 to 58ac.788e.2807 2.3 12.2(18r)S1 15.5(1)SY Ok
4 84b8.020b.a580 to 84b8.020b.a58f 2.3 12.2(18r)S1 15.5(1)SY Ok
5 503d.e531.4b3b to 503d.e531.4b42 2.1 12.2(50r)SYS 15.5(1)SY Ok
6 bc16.655b.d36f to bc16.655b.d376 2.1 12.2(50r)SYS 15.5(1)SY Ok
Mod Sub-Module Model Serial Hw Status
---- --------------------------- ------------------ ----------- ------- -------
1 Distributed Forwarding Card WS-F6K-DFC4-A SAL1909ADKH 2.4 Ok
2 Distributed Forwarding Card WS-F6K-DFC4-A SAL1909ADKG 2.4 Ok
3 Distributed Forwarding Card WS-F6K-DFC4-E SAL2002WEAP 1.2 Ok
4 Distributed Forwarding Card WS-F6K-DFC4-E SAL19089VDG 1.2 Ok
5 Policy Feature Card 4 VS-F6K-PFC4 SAL19089VMX 3.0 Ok
5 CPU Daughterboard VS-F6K-MSFC5 SAL18464A1A 3.0 Ok
6 Policy Feature Card 4 VS-F6K-PFC4 SAL19079TU3 3.0 Ok
6 CPU Daughterboard VS-F6K-MSFC5 SAL18432S2R 3.0 Ok
Mod Online Diag Status
---- -------------------
1 Pass
2 Pass
3 Pass
4 Pass
5 Pass
6 Pass
Router#sh ver
Cisco IOS Software, s2t54 Software (s2t54-ADVENTERPRISEK9-M), Version 15.5(1)SY, RELEASE SOFTWARE (fc6)
Copyright (c) 1986-2017 by Cisco Systems, Inc.
Compiled Sun 30-Apr-17 01:23 by prod_rel_team
ROM: System Bootstrap, Version 12.2(50r)SYS3, RELEASE SOFTWARE (fc1)
Router uptime is 4 minutes
Uptime for this control processor is 5 minutes
System returned to ROM by reload at 00:05:40 UTC Mon Sep 3 2018
System image file is "bootdisk:s2t54-adventerprisek9-mz.SPA.155-1.SY.bin"
Last reload reason: Reload Command
This product contains cryptographic features and is subject to United
States and local country laws governing import, export, transfer and
use. Delivery of Cisco cryptographic products does not imply
third-party authority to import, export, distribute or use encryption.
Importers, exporters, distributors and users are responsible for
compliance with U.S. and local country laws. By using this product you
agree to comply with applicable laws and regulations. If you are unable
to comply with U.S. and local laws, return this product immediately.
cisco WS-C6509-E (M8572) processor (revision ) with 1785856K/262144K bytes of memory.
Processor board ID SMG1906N01B
CPU: MPC8572_E, Version: 2.2, (0x80E80022)
CORE: E500, Version: 3.0, (0x80210030)
CPU:1500MHz, CCB:600MHz, DDR:600MHz
L1: D-cache 32 kB enabled
I-cache 32 kB enabled
Last reset from s/w reset
1 Virtual Ethernet interface
54 Gigabit Ethernet interfaces
36 Ten Gigabit Ethernet interfaces
2543K bytes of non-volatile configuration memory.
Configuration register is 0x2142
Router#sh boot
BOOT variable = bootdisk:s2t54-adventerprisek9-mz.SPA.155-1.SY.bin,12;
CONFIG_FILE variable =
BOOTLDR variable =
Configuration register is 0x2142
Standby BOOT variable = bootdisk:s2t54-adventerprisek9-mz.SPA.155-1.SY.bin,12;
Standby CONFIG_FILE variable =
Standby BOOTLDR variable =
Standby Configuration register is 0x2142
Router#sh inv
NAME: "WS-C6509-E", DESCR: "Cisco Systems, Inc. Catalyst 6500 9-slot Chassis System"
PID: WS-C6509-E , VID: V06, SN: SMG1906N01B
NAME: "WS-C6K-VTT-E 1", DESCR: "VTT-E FRU 1"
PID: WS-C6K-VTT-E , VID: , SN: SMT1810C703
NAME: "WS-C6K-VTT-E 2", DESCR: "VTT-E FRU 2"
PID: WS-C6K-VTT-E , VID: , SN: SMT1810B992
NAME: "WS-C6K-VTT-E 3", DESCR: "VTT-E FRU 3"
PID: WS-C6K-VTT-E , VID: , SN: SMT1810C130
NAME: "CLK-7600 1", DESCR: "OSR-7600 Clock FRU 1"
PID: CLK-7600 , VID: , SN: SMT1752E767
NAME: "CLK-7600 2", DESCR: "OSR-7600 Clock FRU 2"
PID: CLK-7600 , VID: , SN: SMT1752E767
NAME: "1", DESCR: "WS-X6824-SFP CEF720 24 port 1000mb SFP Rev. 2.4"
PID: WS-X6824-SFP , VID: V02, SN: SAL1909ADKH
NAME: "WS-F6K-DFC4-A Distributed Forwarding Card 4 EARL sub-module of 1", DESCR: "WS-F6K-DFC4-A Distributed Forwarding Card 4 Rev. 2.4"
PID: WS-F6K-DFC4-A , VID: , SN: SAL1909ADKH
NAME: "2", DESCR: "WS-X6824-SFP CEF720 24 port 1000mb SFP Rev. 2.4"
PID: WS-X6824-SFP , VID: V02, SN: SAL1909ADKG
NAME: "WS-F6K-DFC4-A Distributed Forwarding Card 4 EARL sub-module of 2", DESCR: "WS-F6K-DFC4-A Distributed Forwarding Card 4 Rev. 2.4"
PID: WS-F6K-DFC4-A , VID: , SN: SAL1909ADKG
NAME: "3", DESCR: "WS-X6816-10GE CEF720 16 port 10GE Rev. 2.3"
PID: WS-X6816-10GE , VID: V03, SN: SAL2002WH7D
NAME: "WS-F6K-DFC4-E Distributed Forwarding Card 4 EARL sub-module of 3", DESCR: "WS-F6K-DFC4-E Distributed Forwarding Card 4 Rev. 1.2"
PID: WS-F6K-DFC4-E , VID: V03, SN: SAL2002WEAP
NAME: "4", DESCR: "WS-X6816-10GE CEF720 16 port 10GE Rev. 2.3"
PID: WS-X6816-10GE , VID: V03, SN: SAL19048KG1
NAME: "WS-F6K-DFC4-E Distributed Forwarding Card 4 EARL sub-module of 4", DESCR: "WS-F6K-DFC4-E Distributed Forwarding Card 4 Rev. 1.2"
PID: WS-F6K-DFC4-E , VID: V03, SN: SAL19089VDG
NAME: "5", DESCR: "VS-SUP2T-10G 5 ports Supervisor Engine 2T 10GE w/ CTS Rev. 2.1"
PID: VS-SUP2T-10G , VID: V06, SN: SAL1906917H
NAME: "msfc sub-module of 5", DESCR: "VS-F6K-MSFC5 CPU Daughterboard Rev. 3.0"
PID: VS-F6K-MSFC5 , VID: , SN: SAL18464A1A
NAME: "VS-F6K-PFC4 Policy Feature Card 4 EARL sub-module of 5", DESCR: "VS-F6K-PFC4 Policy Feature Card 4 Rev. 3.0"
PID: VS-F6K-PFC4 , VID: V04, SN: SAL19089VMX
NAME: "6", DESCR: "VS-SUP2T-10G 5 ports Supervisor Engine 2T 10GE w/ CTS Rev. 2.1"
PID: VS-SUP2T-10G , VID: V06, SN: SAL18432T0L
NAME: "msfc sub-module of 6", DESCR: "VS-F6K-MSFC5 CPU Daughterboard Rev. 3.0"
PID: VS-F6K-MSFC5 , VID: , SN: SAL18432S2R
NAME: "VS-F6K-PFC4 Policy Feature Card 4 EARL sub-module of 6", DESCR: "VS-F6K-PFC4 Policy Feature Card 4 Rev. 3.0"
PID: VS-F6K-PFC4 , VID: V04, SN: SAL19079TU3
NAME: "WS-C6509-E-FAN 1", DESCR: "Enhanced 9-slot Fan Tray 1"
PID: WS-C6509-E-FAN , VID: V05, SN: SMC1904600U
NAME: "PS 1 WS-CAC-6000W", DESCR: "AC power supply, 6000 watt 1"
PID: WS-CAC-6000W , VID: V06, SN: ART1849F1NX
NAME: "PS 2 WS-CAC-6000W", DESCR: "AC power supply, 6000 watt 2"
PID: WS-CAC-6000W , VID: V06, SN: ART1849F1P8
Router#sh power
system power redundancy mode = redundant
system power total = 2671.20 Watts (63.60 Amps @ 42V)
system power used = 2470.44 Watts (58.82 Amps @ 42V)
system power available = 200.76 Watts ( 4.78 Amps @ 42V)
Power-Capacity PS-Fan Output Oper
PS Type Watts A @42V Status Status State
---- ------------------ ------- ------ ------ ------ -----
1 WS-CAC-6000W 2671.20 63.60 OK OK on
2 WS-CAC-6000W 2671.20 63.60 OK OK on
Pwr-Allocated Oper
Fan Type Watts A @42V State
---- ------------------ ------- ------ -----
1 WS-C6509-E-FAN 210.00 5.00 OK
Pwr-Requested Pwr-Allocated Admin Oper
Slot Card-Type Watts A @42V Watts A @42V State State
---- ------------------ ------- ------ ------- ------ ----- -----
1 WS-X6824-SFP 206.22 4.91 206.22 4.91 on on
2 WS-X6824-SFP 206.22 4.91 206.22 4.91 on on
3 WS-X6816-10GE 488.46 11.63 488.46 11.63 on on
4 WS-X6816-10GE 488.46 11.63 488.46 11.63 on on
5 VS-SUP2T-10G 435.54 10.37 435.54 10.37 on on
6 VS-SUP2T-10G 435.54 10.37 435.54 10.37 on on
system auxiliary power mode = off
system auxiliary power redundancy operationally = non-redundant
system primary connector power limit = 10920.00 Watts (260.00 Amps @ 42V)
system auxiliary connector power limit = 10500.00 Watts (250.00 Amps @ 42V)
system primary power used = 2470.44 Watts (58.82 Amps @ 42V)
system auxiliary power used = 0 Watt
Router#sh env
environmental alarms:
no alarms
backplane: operating clock count: 2
operating VTT count: 3
operating fan count: 1
fan-tray 1:
fan-tray 1 type: WS-C6509-E-FAN
fan-tray 1 mode: High-power
fan-tray 1 fan-fail: OK
VTT 1:
VTT 1 OK: OK
VTT 1 outlet temperature: 31C
VTT 2:
VTT 2 OK: OK
VTT 2 outlet temperature: 27C
VTT 3:
VTT 3 OK: OK
VTT 3 outlet temperature: 34C
clock 1:
clock 1 OK: OK, clock 1 clock-inuse: in-use
clock 2:
clock 2 OK: OK, clock 2 clock-inuse: not-in-use
power-supply 1:
power-supply 1 fan-fail: OK
power-supply 1 power-input: AC low
power-supply 1 power-output-mode: low
power-supply 1 power-output-fail: OK
power-supply 2:
power-supply 2 fan-fail: OK
power-supply 2 power-input: AC low
power-supply 2 power-output-mode: low
power-supply 2 power-output-fail: OK
module 1:
module 1 power-output-fail: OK
module 1 outlet temperature: 28C
module 1 inlet temperature: 26C
module 1 device-1 temperature: 27C
module 1 device-2 temperature: 31C
module 1 EARL outlet temperature: 31C
module 1 EARL inlet temperature: 26C
module 2:
module 2 power-output-fail: OK
module 2 outlet temperature: 28C
module 2 inlet temperature: 25C
module 2 device-1 temperature: 26C
module 2 device-2 temperature: 30C
module 2 EARL outlet temperature: 29C
module 2 EARL inlet temperature: 26C
module 3:
module 3 power-output-fail: OK
module 3 outlet temperature: 35C
module 3 inlet temperature: 32C
module 3 asic-1 temperature: 42C
module 3 asic-2 temperature: 44C
module 3 EARL outlet temperature: 34C
module 3 EARL inlet temperature: 28C
module 4:
module 4 power-output-fail: OK
module 4 outlet temperature: 34C
module 4 inlet temperature: 31C
module 4 asic-1 temperature: 41C
module 4 asic-2 temperature: 43C
module 4 EARL outlet temperature: 34C
module 4 EARL inlet temperature: 27C
module 5:
module 5 power-output-fail: OK
module 5 outlet temperature: 35C
module 5 inlet temperature: 26C
module 5 device-1 temperature: 32C
module 5 device-2 temperature: 32C
module 5 asic-1 temperature: 58C
module 5 asic-2 temperature: 44C
module 5 asic-3 temperature: 37C
module 5 asic-4 temperature: 56C
module 5 asic-5 temperature: 41C
module 5 asic-7 temperature: 41C
module 5 asic-8 temperature: 60C
module 5 RP outlet temperature: 32C
module 5 RP inlet temperature: 29C
module 5 RP device-1 temperature: 42C
module 5 EARL outlet temperature: 32C
module 5 EARL inlet temperature: 27C
module 5 EARL device-1 temperature: 58C
module 5 EARL device-2 temperature: 59C
module 6:
module 6 power-output-fail: OK
module 6 outlet temperature: 36C
module 6 inlet temperature: 26C
module 6 device-1 temperature: 32C
module 6 device-2 temperature: 33C
module 6 asic-1 temperature: 54C
module 6 asic-2 temperature: 43C
module 6 asic-3 temperature: 37C
module 6 asic-4 temperature: 56C
module 6 asic-5 temperature: 41C
module 6 asic-7 temperature: 41C
module 6 asic-8 temperature: 59C
module 6 RP outlet temperature: 33C
module 6 RP inlet temperature: 29C
module 6 RP device-1 temperature: 42C
module 6 EARL outlet temperature: 32C
module 6 EARL inlet temperature: 27C
module 6 EARL device-1 temperature: 60C
module 6 EARL device-2 temperature: 60C
chassis connector rating: 1302.00 Watts (31.00 Amps @ 42V)
chassis auxiliary connector rating: 2016.00 Watts (48.00 Amps @ 42V)
module 1
module 1 connector rating: 2016.00 Watts (48.00 Amps @ 42V)
module 1 power consumption: 206.22 Watts ( 4.91 Amps @ 42V)
module 2
module 2 connector rating: 2016.00 Watts (48.00 Amps @ 42V)
module 2 power consumption: 206.22 Watts ( 4.91 Amps @ 42V)
module 3
module 3 connector rating: 751.80 Watts (17.90 Amps @ 42V)
module 3 power consumption: 488.46 Watts (11.63 Amps @ 42V)
module 4
module 4 connector rating: 751.80 Watts (17.90 Amps @ 42V)
module 4 power consumption: 488.46 Watts (11.63 Amps @ 42V)
module 5
module 5 connector rating: 1260.00 Watts (30.00 Amps @ 42V)
module 5 power consumption: 435.54 Watts (10.37 Amps @ 42V)
module 6
module 6 connector rating: 1260.00 Watts (30.00 Amps @ 42V)
module 6 power consumption: 435.54 Watts (10.37 Amps @ 42V)
chassis per slot cooling capacity: 94 cfm
ambient temperature: < 55C
module 1 cooling requirement: 70 cfm
module 2 cooling requirement: 70 cfm
module 3 cooling requirement: 84 cfm
module 4 cooling requirement: 84 cfm
module 5 cooling requirement: 84 cfm
module 6 cooling requirement: 84 cfm
Router#dir all
Directory of nvram:/
2544 -rw- 10495 Sep 3 2018 00:05:08 +00:00 startup-config
2545 -rw- 25 Sep 3 2018 00:05:08 +00:00 private-config
2546 -rw- 10495 Sep 3 2018 00:05:08 +00:00 underlying-config
2 -rw- 0 Sep 3 2018 00:05:08 +00:00 ifIndex-table
4 -rw- 216 Sep 3 2018 00:08:54 +00:00 persistent-data
6 -rw- 0 Sep 3 2018 00:08:04 +00:00 rf_cold_starts
2552192 bytes total (2519680 bytes free)
Directory of system:/
2 -r-- 0 <no date> default-running-config
3 drwx 0 <no date> image
25 dr-x 0 <no date> memory
1 -rw- 11061 <no date> running-config
24 dr-x 0 <no date> vfiles
No space information available
Directory of tmpsys:/
120 drw- 0 <no date> call-home
6 drw- 0 <no date> eem_lib_system
5 drw- 0 <no date> eem_lib_user
65 -rw- 0 <no date> eem_pnt_0
67 -rw- 0 <no date> eem_pnt_1
85 -rw- 0 <no date> eem_pnt_10
87 -rw- 0 <no date> eem_pnt_11
89 -rw- 0 <no date> eem_pnt_12
91 -rw- 0 <no date> eem_pnt_13
93 -rw- 0 <no date> eem_pnt_14
95 -rw- 0 <no date> eem_pnt_15
69 -rw- 0 <no date> eem_pnt_2
71 -rw- 0 <no date> eem_pnt_3
73 -rw- 0 <no date> eem_pnt_4
75 -rw- 0 <no date> eem_pnt_5
77 -rw- 0 <no date> eem_pnt_6
79 -rw- 0 <no date> eem_pnt_7
81 -rw- 0 <no date> eem_pnt_8
83 -rw- 0 <no date> eem_pnt_9
4 drw- 0 <no date> eem_policy
8 drw- 0 <no date> eem_pub
64 -rw- 0 <no date> eem_rpc_0
66 -rw- 0 <no date> eem_rpc_1
84 -rw- 0 <no date> eem_rpc_10
86 -rw- 0 <no date> eem_rpc_11
88 -rw- 0 <no date> eem_rpc_12
90 -rw- 0 <no date> eem_rpc_13
92 -rw- 0 <no date> eem_rpc_14
94 -rw- 0 <no date> eem_rpc_15
68 -rw- 0 <no date> eem_rpc_2
70 -rw- 0 <no date> eem_rpc_3
72 -rw- 0 <no date> eem_rpc_4
74 -rw- 0 <no date> eem_rpc_5
76 -rw- 0 <no date> eem_rpc_6
78 -rw- 0 <no date> eem_rpc_7
80 -rw- 0 <no date> eem_rpc_8
82 -rw- 0 <no date> eem_rpc_9
7 drw- 0 <no date> eem_temp
1 dr-x 0 <no date> lib
9 drw- 0 <no date> macro_scripts
No space information available
Directory of const_nvram:/
1 -rw- 6336 <no date> vlan.dat
1048556 bytes total (1042220 bytes free)
Directory of bootdisk:/
2 -rw- 33554432 Nov 30 1999 03:17:42 +00:00 sea_console.dat
3 -rw- 82942776 Nov 30 1999 03:23:02 +00:00 s2t54-ipbasek9-mz.SPA.150-1.SY6.bin
4 -rw- 33554432 Nov 30 1999 03:20:44 +00:00 sea_log.dat
5 -rw- 164618404 Sep 2 2018 23:48:38 +00:00 s2t54-adventerprisek9-mz.SPA.155-1.SY.bin
1024557056 bytes total (709853184 bytes free)
Directory of disk0:/
3 -rw- 164618404 Sep 2 2018 19:51:06 +00:00 s2t54-adventerprisek9-mz.SPA.155-1.SY.bin
4 -rw- 43217164 Sep 2 2018 19:52:30 +00:00 s2t54-boot-mz.SPA.155-1.SY.bin
512106496 bytes total (304242688 bytes free)
Directory of microcode:/
0 dr-- <no size> <no date>
1 -r-- 16406334 <no date> C2LC
2 -r-- 23265926 <no date> C4LC
3 -r-- 16974762 <no date> TRIFECTA
4 -r-- 18831362 <no date> FEX
5 -r-- 26808322 <no date> FEX_C2K_C3560CX
6 -r-- 333686 <no date> LCP_LX10100
7 -r-- 303612 <no date> LCP_LX1000
8 -r-- 325760 <no date> LCP_AX1000
9 -r-- 376794 <no date> LCP_AX10100
10 -r-- 375182 <no date> LCP_CPFAB
11 -r-- 753454 <no date> LCP_CPGBIT
12 -r-- 489134 <no date> LCP_CP10G
13 -r-- 814686 <no date> LCP_CPMBIT2
14 -r-- 902414 <no date> LCP_CPMBIT
15 -r-- 1302606 <no date> LCP_CPXBIT
16 -r-- 65318 <no date> LCP_ABOOT
17 -r-- 60490 <no date> LCP_BOOT
108389906 bytes total (0 bytes free)
Directory of slavenvram:/
2544 -rw- 10495 Sep 2 2018 19:28:04 +00:00 startup-config
2545 -rw- 25 Sep 2 2018 19:28:04 +00:00 private-config
2546 -rw- 10495 Sep 2 2018 19:28:04 +00:00 underlying-config
2 -rw- 0 Sep 3 2018 00:10:40 +00:00 rf_cold_starts
4 -rw- 269 Sep 3 2018 00:10:44 +00:00 persistent-data
5 -rw- 13 Sep 3 2018 00:10:40 +00:00 snmpid-file
6 -rw- 0 Sep 3 2018 00:10:32 +00:00 ifIndex-table
2552192 bytes total (2515616 bytes free)
Directory of slaveconst_nvram:/
1 -rw- 6336 <no date> vlan.dat
1048556 bytes total (1042220 bytes free)
Directory of slavebootdisk:/
2 -rw- 33554432 Nov 30 1999 03:07:26 +00:00 sea_console.dat
3 -rw- 82942776 Nov 30 1999 03:12:30 +00:00 s2t54-ipbasek9-mz.SPA.150-1.SY6.bin
4 -rw- 164618404 Sep 3 2018 00:02:50 +00:00 s2t54-adventerprisek9-mz.SPA.155-1.SY.bin
6 drw- 0 Sep 3 2018 00:08:48 +00:00 onep
5 -rw- 33554432 Nov 30 1999 03:21:08 +00:00 sea_log.dat
1024557056 bytes total (709820416 bytes free)
Directory of slavesystem:/
2 -r-- 0 <no date> default-running-config
3 drwx 0 <no date> image
25 dr-x 0 <no date> memory
1 -rw- 11061 <no date> running-config
24 dr-x 0 <no date> vfiles
No space information available
Directory of dfc#1-bootflash:/
20 -rw- 910 Mar 21 2015 18:41:13 +00:00 logfile_Jun_13_2014_09_19_02_1
40 -rw- 910 Mar 22 2015 04:15:09 +00:00 logfile_Jun_13_2014_09_19_02_2
41 -rw- 40592 Sep 3 2018 00:09:45 +00:00 lc_monitor_dump_20180903-000945
42 -rw- 40593 Sep 3 2018 00:09:47 +00:00 lc_monitor_dump_20180903-000947
43 -rw- 40745 Sep 3 2018 00:09:49 +00:00 lc_monitor_dump_20180903-000949
44 -rw- 41950 Sep 3 2018 00:09:51 +00:00 lc_monitor_dump_20180903-000951
45 -rw- 43165 Sep 3 2018 00:10:00 +00:00 lc_monitor_dump_20180903-001000
46 -rw- 43333 Sep 3 2018 00:10:02 +00:00 lc_monitor_dump_20180903-001002
15990784 bytes total (15710664 bytes free)
Directory of dfc#2-bootflash:/
20 -rw- 910 Mar 21 2015 18:34:01 +00:00 logfile_Jun_13_2014_09_19_02_1
40 -rw- 910 Mar 22 2015 04:07:53 +00:00 logfile_Jun_13_2014_09_19_02_2
41 -rw- 40591 Sep 3 2018 00:09:46 +00:00 lc_monitor_dump_20180903-000946
42 -rw- 40592 Sep 3 2018 00:09:48 +00:00 lc_monitor_dump_20180903-000948
43 -rw- 41794 Sep 3 2018 00:09:50 +00:00 lc_monitor_dump_20180903-000950
44 -rw- 42550 Sep 3 2018 00:09:52 +00:00 lc_monitor_dump_20180903-000952
45 -rw- 42549 Sep 3 2018 00:09:54 +00:00 lc_monitor_dump_20180903-000954
46 -rw- 42634 Sep 3 2018 00:09:56 +00:00 lc_monitor_dump_20180903-000956
15990784 bytes total (15710312 bytes free)
Directory of dfc#3-bootflash:/
16 -rw- 789 Jan 8 2016 18:40:36 +00:00 logfile_Aug_3_2012_07_06_19_1
17 -rw- 232655 Sep 23 2016 20:30:26 +00:00 crashinfo_20160923-163026-EDT
18 -rw- 40744 Sep 3 2018 00:10:00 +00:00 lc_monitor_dump_20180903-001000
19 -rw- 40911 Sep 3 2018 00:10:02 +00:00 lc_monitor_dump_20180903-001002
20 -rw- 40745 Sep 3 2018 00:10:05 +00:00 lc_monitor_dump_20180903-001004
21 -rw- 41794 Sep 3 2018 00:10:08 +00:00 lc_monitor_dump_20180903-001007
22 -rw- 42112 Sep 3 2018 00:10:09 +00:00 lc_monitor_dump_20180903-001009
23 -rw- 42077 Sep 3 2018 00:10:11 +00:00 lc_monitor_dump_20180903-001011
15990784 bytes total (15497868 bytes free)
Directory of dfc#4-bootflash:/
16 -rw- 789 Feb 15 2015 18:57:29 +00:00 logfile_Aug_3_2012_07_06_19_1
17 -rw- 41777 Sep 3 2018 00:10:17 +00:00 lc_monitor_dump_20180903-001017
18 -rw- 41777 Sep 3 2018 00:10:20 +00:00 lc_monitor_dump_20180903-001020
19 -rw- 41778 Sep 3 2018 00:10:22 +00:00 lc_monitor_dump_20180903-001022
20 -rw- 41927 Sep 3 2018 00:10:24 +00:00 lc_monitor_dump_20180903-001024
21 -rw- 41928 Sep 3 2018 00:10:26 +00:00 lc_monitor_dump_20180903-001026
22 -rw- 42529 Sep 3 2018 00:10:28 +00:00 lc_monitor_dump_20180903-001028
15990784 bytes total (15727340 bytes free)
Router#sh diagn res mod all
Current bootup diagnostic level: minimal
Module 1: CEF720 24 port 1000mb SFP SerialNo : SAL1909ADKH
Overall Diagnostic Result for Module 1 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestTransceiverIntegrity:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
2) TestLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
. . . . . . . . . . . . . . . . . . . . . . . .
3) TestScratchRegister -------------> .
4) TestSynchedFabChannel -----------> .
5) TestNewIndexLearn ---------------> .
6) TestDontConditionalLearn --------> .
7) TestBpduTrap --------------------> .
8) TestMatchCapture ----------------> .
9) TestProtocolMatch ---------------> .
10) TestPortSecurity ----------------> .
11) TestMacNotification -------------> .
12) TestIPv4FibShortcut -------------> .
13) TestL3Capture2 ------------------> .
14) TestIPv6FibShortcut -------------> .
15) TestMPLSFibShortcut -------------> .
16) TestNATFibShortcut --------------> .
17) TestAclPermit -------------------> .
18) TestAclDeny ---------------------> .
19) TestAclRedirect -----------------> .
20) TestRBAcl -----------------------> .
21) TestQos -------------------------> .
22) TestL3VlanMet -------------------> .
23) TestIngressSpan -----------------> .
24) TestEgressSpan ------------------> .
25) TestNetflowShortcut -------------> .
26) TestInbandEdit ------------------> .
27) TestFirmwareDiagStatus ----------> .
28) TestAsicSync --------------------> .
29) TestOBFL ------------------------> .
30) TestErrorCounterMonitor ---------> .
31) TestUnusedPortLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U . U U U U U U U U U U U .
32) TestPortTxMonitoring:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
33) TestEobcStressPing --------------> U
34) TestFibTcam ---------------------> U
35) TestAclQosTcam ------------------> U
36) TestEarlMemOnBootup -------------> .
37) TestAsicMemory ------------------> U
38) TestLtlFpoeMemoryConsistency ----> .
39) TestRwEngineOverSubscription ----> U
40) TestEARLInternalTables ----------> U
Module 2: CEF720 24 port 1000mb SFP SerialNo : SAL1909ADKG
Overall Diagnostic Result for Module 2 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestTransceiverIntegrity:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
2) TestLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
. . . . . . . . . . . . . . . . . . . . . . . .
3) TestScratchRegister -------------> .
4) TestSynchedFabChannel -----------> .
5) TestNewIndexLearn ---------------> .
6) TestDontConditionalLearn --------> .
7) TestBpduTrap --------------------> .
8) TestMatchCapture ----------------> .
9) TestProtocolMatch ---------------> .
10) TestPortSecurity ----------------> .
11) TestMacNotification -------------> .
12) TestIPv4FibShortcut -------------> .
13) TestL3Capture2 ------------------> .
14) TestIPv6FibShortcut -------------> .
15) TestMPLSFibShortcut -------------> .
16) TestNATFibShortcut --------------> .
17) TestAclPermit -------------------> .
18) TestAclDeny ---------------------> .
19) TestAclRedirect -----------------> .
20) TestRBAcl -----------------------> .
21) TestQos -------------------------> .
22) TestL3VlanMet -------------------> .
23) TestIngressSpan -----------------> .
24) TestEgressSpan ------------------> .
25) TestNetflowShortcut -------------> .
26) TestInbandEdit ------------------> .
27) TestFirmwareDiagStatus ----------> .
28) TestAsicSync --------------------> .
29) TestOBFL ------------------------> .
30) TestErrorCounterMonitor ---------> .
31) TestUnusedPortLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U . U U U U U U U U U U U .
32) TestPortTxMonitoring:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
33) TestEobcStressPing --------------> U
34) TestFibTcam ---------------------> U
35) TestAclQosTcam ------------------> U
36) TestEarlMemOnBootup -------------> .
37) TestAsicMemory ------------------> U
38) TestLtlFpoeMemoryConsistency ----> .
39) TestRwEngineOverSubscription ----> U
40) TestEARLInternalTables ----------> U
Module 3: CEF720 16 port 10GE SerialNo : SAL2002WH7D
Overall Diagnostic Result for Module 3 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestTransceiverIntegrity:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
2) TestLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
. . . . . . . . . . . . . . . .
3) TestScratchRegister -------------> .
4) TestNonDisruptiveLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
5) TestSynchedFabChannel -----------> .
6) TestNewIndexLearn ---------------> .
7) TestDontConditionalLearn --------> .
8) TestBpduTrap --------------------> .
9) TestMatchCapture ----------------> .
10) TestProtocolMatch ---------------> .
11) TestPortSecurity ----------------> .
12) TestMacNotification -------------> .
13) TestIPv4FibShortcut -------------> .
14) TestL3Capture2 ------------------> .
15) TestIPv6FibShortcut -------------> .
16) TestMPLSFibShortcut -------------> .
17) TestNATFibShortcut --------------> .
18) TestAclPermit -------------------> .
19) TestAclDeny ---------------------> .
20) TestAclRedirect -----------------> .
21) TestRBAcl -----------------------> .
22) TestQos -------------------------> .
23) TestL3VlanMet -------------------> .
24) TestIngressSpan -----------------> .
25) TestEgressSpan ------------------> .
26) TestNetflowShortcut -------------> .
27) TestInbandEdit ------------------> .
28) TestFirmwareDiagStatus ----------> .
29) TestAsicSync --------------------> .
30) TestOBFL ------------------------> .
31) TestErrorCounterMonitor ---------> U
32) TestUnusedPortLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U . U U U . U U U . U U U .
33) TestPortTxMonitoring:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
34) TestEobcStressPing --------------> U
35) TestFibTcam ---------------------> U
36) TestAclQosTcam ------------------> U
37) TestEarlMemOnBootup -------------> .
38) TestAsicMemory ------------------> U
39) TestLtlFpoeMemoryConsistency ----> .
40) TestRwEngineOverSubscription ----> U
41) TestEARLInternalTables ----------> U
42) TestMediaLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
43) TestMicroburst:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
Module 4: CEF720 16 port 10GE SerialNo : SAL19048KG1
Overall Diagnostic Result for Module 4 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestTransceiverIntegrity:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
2) TestLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
. . . . . . . . . . . . . . . .
3) TestScratchRegister -------------> .
4) TestNonDisruptiveLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
5) TestSynchedFabChannel -----------> .
6) TestNewIndexLearn ---------------> .
7) TestDontConditionalLearn --------> .
8) TestBpduTrap --------------------> .
9) TestMatchCapture ----------------> .
10) TestProtocolMatch ---------------> .
11) TestPortSecurity ----------------> .
12) TestMacNotification -------------> .
13) TestIPv4FibShortcut -------------> .
14) TestL3Capture2 ------------------> .
15) TestIPv6FibShortcut -------------> .
16) TestMPLSFibShortcut -------------> .
17) TestNATFibShortcut --------------> .
18) TestAclPermit -------------------> .
19) TestAclDeny ---------------------> .
20) TestAclRedirect -----------------> .
21) TestRBAcl -----------------------> .
22) TestQos -------------------------> .
23) TestL3VlanMet -------------------> .
24) TestIngressSpan -----------------> .
25) TestEgressSpan ------------------> .
26) TestNetflowShortcut -------------> .
27) TestInbandEdit ------------------> .
28) TestFirmwareDiagStatus ----------> .
29) TestAsicSync --------------------> .
30) TestOBFL ------------------------> .
31) TestErrorCounterMonitor ---------> U
32) TestUnusedPortLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U . U U U . U U U . U U U .
33) TestPortTxMonitoring:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
34) TestEobcStressPing --------------> U
35) TestFibTcam ---------------------> U
36) TestAclQosTcam ------------------> U
37) TestEarlMemOnBootup -------------> .
38) TestAsicMemory ------------------> U
39) TestLtlFpoeMemoryConsistency ----> .
40) TestRwEngineOverSubscription ----> U
41) TestEARLInternalTables ----------> U
42) TestMediaLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
43) TestMicroburst:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
----------------------------------------------------
U U U U U U U U U U U U U U U U
Module 5: Supervisor Engine 2T 10GE w/ CTS (Active) SerialNo : SAL1906917H
Overall Diagnostic Result for Module 5 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestTransceiverIntegrity:
Port 1 2 3 4 5
-------------------
U U U U U
2) TestLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
3) TestActiveToStandbyLoopback:
Port 1 2 3 4 5
-------------------
U U U U U
4) TestL2CTSLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
5) TestL3CTSLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
6) TestScratchRegister -------------> .
7) TestNewIndexLearn ---------------> .
8) TestDontConditionalLearn --------> .
9) TestBpduTrap --------------------> .
10) TestMatchCapture ----------------> .
11) TestProtocolMatchChannel --------> .
12) TestMacNotification -------------> U
13) TestPortSecurity ----------------> .
14) TestIPv4FibShortcut -------------> .
15) TestL3Capture2 ------------------> .
16) TestIPv6FibShortcut -------------> .
17) TestMPLSFibShortcut -------------> .
18) TestNATFibShortcut --------------> .
19) TestAclPermit -------------------> .
20) TestAclDeny ---------------------> .
21) TestAclRedirect -----------------> .
22) TestRBAcl -----------------------> .
23) TestQos -------------------------> .
24) TestDQUP ------------------------> .
25) TestL3VlanMet -------------------> .
26) TestIngressSpan -----------------> .
27) TestEgressSpan ------------------> .
28) TestNetflowShortcut -------------> .
29) TestInbandEdit ------------------> .
30) TestFabricInternalSnake ---------> .
31) TestFabricExternalSnake ---------> .
32) TestFabricVlanLoopback ----------> .
33) TestTrafficStress ---------------> U
34) TestL3TcamMonitoring ------------> .
35) TestFibTcam ---------------------> U
36) TestAclQosTcam ------------------> U
37) TestEarlMemOnBootup -------------> .
38) TestAsicMemory ------------------> U
39) ScheduleSwitchover --------------> U
40) TestFirmwareDiagStatus ----------> .
41) TestAsicSync --------------------> .
42) TestUnusedPortLoopback:
Port 1 2 3 4 5
-------------------
U U U . .
43) TestNonDisruptiveLoopback:
Port 1 2 3 4 5
-------------------
U U U U U
44) TestFabricFlowControlStatus -----> U
45) TestPortTxMonitoring:
Port 1 2 3 4 5
-------------------
U U U U U
46) TestOBFL ------------------------> .
47) TestCFRW:
Device 1
---------
U
48) TestLtlFpoeMemoryConsistency ----> .
49) TestErrorCounterMonitor ---------> .
50) TestEARLInternalTables ----------> .
51) TestNVRAMBatteryMonitor ---------> U
52) TestMediaLoopback:
Port 1 2 3 4 5
-------------------
U U U U U
53) TestMicroburst:
Port 1 2 3 4 5
-------------------
. . . . .
Module 6: Supervisor Engine 2T 10GE w/ CTS (Hot) SerialNo : SAL18432T0L
Overall Diagnostic Result for Module 6 : PASS
Diagnostic level at card bootup: minimal
Test results: (. = Pass, F = Fail, U = Untested)
1) TestTransceiverIntegrity:
Port 1 2 3 4 5
-------------------
U U U U U
2) TestLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
3) TestActiveToStandbyLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
4) TestL2CTSLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
5) TestL3CTSLoopback:
Port 1 2 3 4 5
-------------------
. . . . .
6) TestScratchRegister -------------> .
7) TestNewIndexLearn ---------------> .
8) TestDontConditionalLearn --------> .
9) TestBpduTrap --------------------> .
10) TestMatchCapture ----------------> .
11) TestProtocolMatchChannel --------> .
12) TestMacNotification -------------> .
13) TestPortSecurity ----------------> .
14) TestIPv4FibShortcut -------------> .
15) TestL3Capture2 ------------------> .
16) TestIPv6FibShortcut -------------> .
17) TestMPLSFibShortcut -------------> .
18) TestNATFibShortcut --------------> .
19) TestAclPermit -------------------> .
20) TestAclDeny ---------------------> .
21) TestAclRedirect -----------------> .
22) TestRBAcl -----------------------> .
23) TestQos -------------------------> .
24) TestDQUP ------------------------> .
25) TestL3VlanMet -------------------> .
26) TestIngressSpan -----------------> .
27) TestEgressSpan ------------------> .
28) TestNetflowShortcut -------------> .
29) TestInbandEdit ------------------> .
30) TestFabricInternalSnake ---------> .
31) TestFabricExternalSnake ---------> U
32) TestFabricVlanLoopback ----------> .
33) TestTrafficStress ---------------> U
34) TestL3TcamMonitoring ------------> .
35) TestFibTcam ---------------------> U
36) TestAclQosTcam ------------------> U
37) TestEarlMemOnBootup -------------> .
38) TestAsicMemory ------------------> U
39) ScheduleSwitchover --------------> U
40) TestFirmwareDiagStatus ----------> .
41) TestAsicSync --------------------> .
42) TestUnusedPortLoopback:
Port 1 2 3 4 5
-------------------
U U U . .
43) TestNonDisruptiveLoopback:
Port 1 2 3 4 5
-------------------
U U U U U
44) TestFabricFlowControlStatus -----> U
45) TestPortTxMonitoring:
Port 1 2 3 4 5
-------------------
U U U U U
46) TestOBFL ------------------------> .
47) TestCFRW:
Device 1
---------
U
48) TestLtlFpoeMemoryConsistency ----> .
49) TestErrorCounterMonitor ---------> .
50) TestEARLInternalTables ----------> U
51) TestNVRAMBatteryMonitor ---------> U
52) TestMediaLoopback:
Port 1 2 3 4 5
-------------------
U U U U U
53) TestMicroburst:
Port 1 2 3 4 5
-------------------
. . . . .
Router#sh license feature
Feature name Enforcement Evaluation Subscription Enabled
MACSec_Encryption yes no no no
CTS yes no no no
TEST_FEATURE_1 yes yes no no
TEST_FEATURE_2 yes yes no no
Router#